Product Advantages
1. High Efficiency and Energy Saving
The system adopts variable frequency control to automatically adjust pump speed according to actual water demand, reducing unnecessary energy consumption.
2. Stable Constant Pressure
Pressure sensors monitor pipeline pressure in real time, and the system automatically adjusts the operating status to maintain stable water supply pressure.
3. Intelligent Control
The system can realize automatic start and stop, multi-pump switching, fault protection, and operation monitoring, reducing the need for manual supervision.
4. Compact Structure
The pumps, control cabinet, pipelines, and pressure stabilizing components are integrated into one system, offering a small footprint and convenient installation and maintenance.
Application Range
1. Residential and Villa Water Supply
Suitable for pressurized domestic water supply systems in new residential communities, high-rise residential buildings, and villa areas.
2. Commercial and Public Building Water Supply
Applicable to office buildings, complex buildings, hotels, restaurants, schools, hospitals, and commercial centers.
3. Municipal Water Secondary Pressurization
Suitable for domestic water pressurization and pipeline pressure compensation in areas where municipal water pressure is insufficient.
4. Water Tank and Reservoir Pressurization Retrofit
Suitable for automatic upgrades of traditional water supply systems using ground tanks, water tanks, and reservoirs.
5. Industrial and Mining Water Supply
Applicable to production water and domestic water systems in factories, mines, industrial parks, and related facilities.
6. Circulating Water and Cooling Water Systems
Suitable for boiler water replenishment, circulating water, cooling water, and supporting water supply systems for equipment.
Technical Parameters
Flow Rate: 0–500 m³/h
Pressure: 0.10–2.7 MPa
Medium Temperature: ≤80°C
Control Mode: Variable frequency constant pressure control
Applicable Medium: Clean water or liquids with physical and chemical properties similar to clean water
Working Pressure: Determined according to project configuration and actual water supply system requirements
Flow Rate: 0–500 m³/h
Pressure: 0.10–2.7 MPa
Medium Temperature: ≤80°C
Control Mode: Variable frequency constant pressure control
Applicable Medium: Clean water or liquids with physical and chemical properties similar to clean water
Working Pressure: Determined according to project configuration and actual water supply system requirements
Certification
Constant Pressure Variable Frequency Water Supply Equipment can be supplied with relevant product documents and quality files according to project requirements, including:
Product qualification certificate
Factory inspection documents
Installation dimension drawing
Operation and maintenance manual
If the project has special requirements for testing standards, control cabinet configuration, component brands, material requirements, or third-party documents, please specify them during the inquiry stage. Final documentation shall be subject to the confirmed technical agreement and actual supply scope.
OEM Customization Service
We provide OEM customization services according to different project requirements, including:
Pump model and quantity configuration
Flow rate, pressure, and power matching
Single-pump, multi-pump, and standby pump control solutions
Customized variable frequency constant pressure control system
Pressure stabilizing tank capacity and pipeline configuration
Control cabinet functions, component brand selection, and communication interface options
Equipment base, appearance color, nameplate, and marking customization
Complete set supply for project-based orders
Customers may provide design flow rate, required water pressure, building type, water supply height, inlet conditions, power supply parameters, installation space, and control requirements. Our team can assist with water supply system selection and configuration.
Installation Instructions
1.Before installation, check whether the equipment model, flow rate, pressure, power supply parameters, control mode, and installation dimensions meet project requirements.
2.The equipment should be installed on a flat, stable, and well-ventilated foundation, with sufficient space reserved for operation, maintenance, and heat dissipation.
3.Inlet and outlet pipelines, valves, pressure gauges, sensors, and electrical wiring should be connected according to the drawings to ensure reliable sealing and secure wiring.
4.Before commissioning, check the pump rotation direction, pipeline valve status, control cabinet parameters, pressure stabilizing tank pressure, and protection functions.
5.During initial operation, observe pressure changes, start-stop status, noise, vibration, temperature rise, and water leakage. The equipment can be put into normal operation after confirming that all conditions are normal.
Frequently Asked Questions
Selection should be based on design flow rate, required water pressure, building height, number of water points, inlet conditions, power supply parameters, and control requirements. Pump quantity, pump power, pressure stabilizing tank, and control cabinet configuration should then be matched accordingly.
Variable frequency constant pressure control automatically adjusts pump speed according to pipeline pressure changes, keeping system pressure within the set range while reducing frequent starts and stops and unnecessary energy consumption.
Yes. According to project requirements, the system can be designed with duty and standby pumps, multi-pump parallel operation, automatic pump rotation, variable frequency pump staging, and automatic fault switching.
Yes. It can be used to upgrade traditional water supply systems such as ground tanks, water tanks, roof tanks, or systems with insufficient municipal water pressure, improving water supply stability and automation.
Common causes include abnormal pressure sensor signals, improper control parameter settings, insufficient pressure stabilizing tank pressure, pipeline leakage, abnormal valve status, or a mismatch between pump selection and actual operating conditions.
Before operation, check power supply voltage, grounding, pipeline connections, valve status, pump rotation direction, control cabinet parameters, pressure sensor signals, and pressure stabilizing tank pressure. Start the system only after confirming that there are no abnormalities.